Name: Cannon CAV-2200AUTOMATIC VISCOMETER
Model: CAV-2200
Brand: Cannon
Application: Viscosity
Category: Viscometer
Standard: GB/T265;ASTM D445;ASTM D446;ISO 3104
Feature:

CANNON®

CAV2200 AUTOMATIC VISCOMETER

  • ASTM D445,ISO 3104,IP71,ASTM D446,ISO3105
  • Modular Benchtop Unit(Small Footprint)
  • Variable Temperature Selection from 20℃ to100℃(150℃ with High-Temperature Option)
  • Viscosity Range of 0.5 to 5000 cSt
  • Powerful VISCPRO®  for Windows®98,2000,NT,and XP® Siftware
  • Bath Unit Dimensions: 305 x 727 x 1245 mm, 12 x 35 x 49 inches (W x D x H)
  • Service Unit Dimensions: 178 x 508 x 356 mm, 7 x 20 x 14 inches (W x D x H)
  • SDU-100 Dimensions: 178 x 508 x 356 mm, 7 x 20 x 14 inches (W x D x H)
  • Viscosity Range: 0.5 to 5000 cSt depending on viscometer tubes
  • Bath Temperature: Variable from 20°C to 100°C with an accuracy better than ±0.01°C. High temperature bath option (up to 150°C, ± 0.03°C) available by request.
  • Drop Time Resolution: 0.01 seconds (timing accuracy to ±0.001 second)
  • Operating Conditions: 10%-90% RH non-condensing. Installation category II;Pollution degree 2
  • Compliance: CE Mark: EMC directive (89/336/EEC); Low voltage directive (73/23/EEC); HI-POT (1900 VDC, 60 sec.) Preferred Bench Height: 28 to 30 inches
  • Computer: Contact CANNON Instrument Company for current specifications and an installation guide detailing space, equipment and utility requirements.
  • CE Marked for Safe, Reliable Performance

CAV Ordering Information

Catalog No.

Item Description

9725-A05

CAV-2100,115 Volts AC,50/60 Hz,1650W

9725-A07

CAV-2200,115 Volts AC,50/60 Hz,1650W

9725-A10

CAV-2100F, 230 volts AC,50/60 Hz, 1750W

9725-A12

CAV-2200F, 230 volts AC,50/60 Hz, 1750W

9725-A15

CAV-2100, 100 volts AC,50/60 Hz, 1750W

9725-A17

CAV-2200, 100 volts AC,50/60 Hz, 1750W

Ordering Information

Catalog No.

Item Description

P61.3427

High-Temperature Bath Option

P61.3425

Heated Sample Tray Option (Left Tray)

P61.3489

Heated Sample Tray Option (Right Tray)

9728-X50

Digital Thermometer (115V)

9728-X51

Platinum Resistance Probe,6-inch (for miniAV)

9728-X52

Platinum Resistance Probe,12-inch (for CAV)

P61.3626

Initial added temperature calibration/configuration

P61.3643

Heat Exchanger Tube (CAV-2200 only)

P61.3415

Analog Thermometer for Heated Trays

P61.3416

Digital Thermometer for Heated Trays

P61.3573

Non-Heated 20-vial Sample Holder

P61.3575

Exhaust Collector Box

P61.3671

10-Cup Sample Holder Option

P61.3620

Spare Parts Option (State Tube Range and Temp when Ordering)

*please specify exact voltage and frequency when ordering

 

Available CAV Tube Sizes

Standard Tubes

Fast-Run Tubes

Kinematic Viscosity Range

0.5-50

-

1-100

1-10

2-200

2-20

3-300

3-30

4-400

4-40

5-500

5-50

6-600

6-60

7-700

7-70

8-800

8-80

10-1000

10-100

15-1500

15-150

20-2000

20-200

30-3000

30-300

40-4000

50-500

Other tube sizes available by special order.

*mm2/s (centistokes)

 