Maximum Dimensions:
|
13.5 x 7.25 x 4.5 in.
34.3 x 18.4 x 11.4 cm
|
Total Weight:
|
3 lbs with 75 ft. of cable
1.4 kg with 23m of cable
|
Battery:
|
Type: 9 volt Alkaline, approved types listed on device.
Life: Approximately 50 hours
Battery manufacturer's battery operating temperature range -4° to 130°F,
-20° to 54°C
Note: Battery may not provide adequate power if ambient temperature is below -4°F, -20°C or above 130°F, 54°C
|
Case Materials:
|
Polypropylene Blend, Stainless Steel and Aluminum.
|
Limited Warranty:
|
90 days on Probe Assembly
1 year on other components
|
Probe:
|
304 Stainless Steel, Sealant, Aramid Fiber Reinforced, FEP or PFA
Cable Jacket, Coaxial Construction
|
Temperature:
|
Resolution 0.1 Degrees
Range* 14 to 370°F, -10 to 188°C
*Lower Range Available For Cold Climates
Calibrated Accuracy:
±0.2°F from 32 to 200°F
±0.5°F, from 200 to 300°F
±0.1°C from 0 to 100°C
±0.3°C from 100 to 150°C
Long term drift not to exceed 0.05%/yr
Meets API requirements.
|